DPF100
The first dedicated tester to check for the minute particles which should be collected by a fully functioning DPF. The tool is much more sensitive than existing smoke meters and can easily identify a faulty or compromised DPF at idle in 30 seconds or less.
Can be operated in stand alone mode to give GOOD/ MARGINAL/POOR result using the built in LEDs or with an Android tablet providing comprehensive graphical indication of DPF performance during the test. Individual tests can be logged and printed along with relevant vehicle details when used with the tablet

Technical Specification
- Dimensions 520mm H x 650mm W x 280mm D (including sample hose)
Stand footprint 270mm x 270mm - Operating Principle
Measurement of PM using light scattering - Weight
8.13 Kilos - Current consumption
4A at 12V DC maximum. Average current is largely determined by ambient temperature - Stand height adjustment
150mm - 450mm

- Particle size range
0.30μm to >10μm. Sensitivity is reduced by 50% at 0. 30μm - Sample hose
500mm long x 30mm diameter J20 R3 rubber
500mm extension with coupler - Sensor life
Approximately1500+tests. Sensor life is dependent on cumulative exposure - Ambient operating temperature
0° C - 40° C. - User controls
START button